Area of application
Prevention of bodily injuries of fingers, hands, and limbs, e.g. when working at:
- wood working machines
- packaging machines
- textile machines
- storing and materials-handling technology
- insertion machines
- revolving machines
- palletizers
Properties
- integrated control-unit with contactor control and restart activatable by DIP switches activatable
- contactor/valves directly connectablly, switching capacity 0,5A/24V
- smallest safety distances by short response times 6 ms to 25 ms, depending of the protection high
- smallest obstacle recognition of 14mm up to 7m range
- hand protection up to detection range of 24 m, recognition of smallest obstacles(30 mm)
- protection heights of 100mm to 1900mm
- microprocessor monitoring of the safety functions
- self-monitoring semiconductor outputs with line interruption monitoring, short-circuit- and side current passages check.
- built in selfdiagnostic with error display
- minimum safety distance due to short response times, between 5 ms and 25 ms, depending on constructional lenght
- protective system IP65